http://oss.vluuke.com/upload/site/2025-02-08/80d25202502081309137942.png
VKCR8600 Portable Leakage Protector Tester
Others
Home > Products > Others
VKCR8600 Portable Leakage Protector Tester
  • VKCR8600 Portable Leakage Protector Tester
  • VKCR8600 Portable Leakage Protector Tester
  • VKCR8600 Portable Leakage Protector Tester
  • VKCR8600 Portable Leakage Protector Tester
  • VKCR8600 Portable Leakage Protector Tester
  • VKCR8600 Portable Leakage Protector Tester
VKCR8600 Portable Leakage Protector Tester
VKCR8600 Portable Leakage Protector Tester
★Used for measure various leakage protector of leakage operating time.
★Test current: 15mA~500mA (10 gears)
★Test range of leakage current operating time: 0~999ms
★Rated voltage: AC 220V
$130.00
  • Features
  • Specifications
  • Model
  • Accessories
  • Docs & Software

1. Test current from 0 to 500mA of 10 gears (15, 30, 50, 75, 100, 150, 200, 250, 300, 500mA). 

2. Test leakage operating time range: 0~999ms. 

3. The instrument is high accuracy, small in size and light in weight, easy to carry, especially suitable for on-site detection of leakage protector.


Power Supply

DC6V alkaline dry battery LR6 1.5V×4

Display Mode

LCD: 128dots×64dots

LCD Size

Display area: 44mm×27mm

Rated Voltage

AC 220V (During leakage protection switch testing, between instrument interface)

Test Line Voltage

220V/380V

Leakage Current Gear

15mA, 30mA, 50mA, 75mA, 100mA, 150mA, 200mA, 250mA, 300mA, 500mA

Gear Current Accuracy

±10%rdg+2dgt

Test Range Of Leakage Current Operating Time

0~999ms

Display Accuracy Of Leakage Operating Time

±5%rdg±3dgt

Failure Message Indication

LCD display “fault” failure information indication, indicates that tested rated operating current gear is low or leakage protector has fault.

Length of test line

1.5m

Test Mode

Manual or automatic

Tester Size

170mm×75mm×30mm

Weight

About 290g (include battery); Total weight: about 350g(include package)

Battery Voltage

When the battery voltage drops to 4.8V, the low battery voltage symbol is displayed to remind the battery to be replaced.The measured data at this time is also accurate.

Working Current

40mA Max

Insulation Withstand Voltage

100MΩ or greater, AC2kV/rms(between the housing and screw)

Suitable Safety Standard

IEC1010-1, IEC1010-2-032, Pollution level 2, CAT Ⅲ(600V) IEC61326(EMC Standard)

Working Temperature & Humidity

-10℃~40℃; below 80%RH

Store Temperature & Humidity

-10℃~60℃; below 70%RH


©2024 Wuhan Lvnengde Precision Testing Technology Co., Ltd.Disclaimer: Part of the information on this site comes from the Internet, if there is any infringement, please contact customer service in time, we will deal with it as soon as possible