http://oss.vluuke.com/upload/site/2025-02-08/80d25202502081309137942.png
VKCR3670 Transformer DC Resistance Tester
Transformer Test Series
Home > Products > Transformer Test Series
VKCR3670 Transformer DC Resistance Tester
  • VKCR3670 Transformer DC Resistance Tester
  • VKCR3670 Transformer DC Resistance Tester
  • VKCR3670 Transformer DC Resistance Tester
  • VKCR3670 Transformer DC Resistance Tester
  • VKCR3670 Transformer DC Resistance Tester
  • VKCR3670 Transformer DC Resistance Tester
VKCR3670 Transformer DC Resistance Tester
VKCR3670 Transformer DC Resistance Tester
★Resistance measurement range: 200.0uΩ~50.00kΩ
★Output Voltage: 24V MAX
★Battery: AC 220V, built-in lithium battery
★Alarm function: setting alarm threshold.
★Memory: data storage 600 groups.
★Built-in printer
★Bluetooth communication
★USB communication interface
$440.00
  • Features
  • Specifications
  • Model
  • Accessories
  • Docs & Software

1. The tester has two power supply modes: AC 220V and built-in large capacity lithium battery, which can meet the user`s requirement in various sites. 

2. Two measurement modes: automatic measurement mode: the test current can be automatically selected according to the load; Manual measurement mode: 7 test current gears can be choose. 

3. The maximum output voltage is 24V, the maximum test current is 10A, and the test speed is fast, which can be applied to various transformers andotherresistance measurements. 

4. Equip with 5-inch true-color LCD touch screen, which is dual-purpose for measuring and operating with touch screen/press buttons. With built-inprinter, Bluetooth communication, USB interface. 

5. With automatic discharge function, with 75° conversion resistance function, which can compensates for the material temperature of the testedobject


Power Supply

AC 220V

Built-in Lithium Battery

DC 22.2V 5200mAh

Display Mode

5 inch true-color LCD touch screen, resolution 480×854

Backlight Adjustment

Drag the slider to adjust the brightness

Measurement Range

1.0uΩ~50.00kΩ

Test Current & Accuracy

200.0uΩ~50.00KΩ       AUTO

200.0uΩ~20.00mΩ       10A               0.2%FS

10.00mΩ~200.0mΩ       5A                0.5%FS

100.0mΩ~2.000Ω        1A                1%FS

1.00Ω~20.00Ω         >100mA Constant pressure method      1%FS

10.0Ω~200.0Ω         >10mA Constant pressure method       1%FS

100Ω~50.00kΩ         >1mA Constant pressure method       1%FS

Max. Resolution

0.1uΩ

Test Current Gear

AUTO, 10A, 5A, 1A, 100mA, 10mA, 1mA

Output Voltage

24V MAX

Measurement Method

Precision four-wire method, 2 A/D simultaneous detection

Measurement Mode

Automatic, manual

Wire Length Test

L: ≤9999m

Standard Wire Length

Standard wire length setting range: 1m~200m

Temperature Measurement Range

-55℃~125℃

Temperature Measurement Accuracy

±0.5℃

Test Time

Sampling AD rate 1 second/time

Alarm Setting

Setting alarm threshold range:1mΩ~2500Ω,the alarm function is not activated at 0Ω

Alarm Prompt

When the test value exceed the set value of the alarm, the buzzer will sound and the alarm will prompt

Overflow Display

Overrange overflow function: digital 999999 overrun display

Charging Indication

The indicator light on the charger light up red when charging, and green when fully charged

Low Voltage Indication

When the battery voltage is lower than DC 22.2V, the battery level symbol is displayed in red, reminding charging in time.

Memory

600 groups(no data will be lost if the battery is powered down or replaced)

Data Hold

Automatically keep displaying the tested result after each test

Clock Function

24-hour clock, showing hours, minutes, and seconds

Calculation Of Reduced Resistance

Convert based on the temperature and material of the tested product.

Discharge Function

Automatic discharge after testing, with clear discharge instruction to avoid misoperation

Automatic Shutdown

After setting the automatic shutdown, it will automatically shut down after 15 minutes of no operation

Host Size

280mm×260mm×160mm

Weight

The instrument: About 3250g (include battery); total weight: about 6.4kg (include accessory)

Working Temperature & Humidity

-10℃~40℃; below 80%RH

Storage Temperature & Humidity

-10℃~60℃; below 70%RH


©2024 Wuhan Lvnengde Precision Testing Technology Co., Ltd.Disclaimer: Part of the information on this site comes from the Internet, if there is any infringement, please contact customer service in time, we will deal with it as soon as possible