1. The tested loop circuit must not live when in testing.
2. Insulation resistance value testing up to Max 8 channel loop circuit.
3. With two modes of manual measurement and RS485 remote measurement, and have Bluetooth control measurement mode.
1. The tested loop circuit must not live when in testing.
2. Insulation resistance value testing up to Max 8 channel loop circuit.
3. With two modes of manual measurement and RS485 remote measurement, and have Bluetooth control measurement mode.
Power Supply | DC 12V(External power supply) |
LCD Size | 21.7mm×10.9mm |
Output Voltage | 50V, 100V, 250V, 500V Self-set |
Short Circuit Current | 5mA MAX |
Resistance Test Range | 0.1MΩ~20GΩ |
Test Accuracy | ±5%rdg±5dgt |
Communication Mode | RS485 communication, Bluetooth communication |
Test Time | Insulation resistance: 20 seconds, dielectric absorption ratio: 1 minute, polarization index: 10 minutes, the test time can also be controlled by communication from 1 second to 10 minutes |
Data Transmission | Insulation resistance value, output voltage, leakage current, dielectric absorption ratio and polarization index |
Test Loop Quantity | 1~8 Channel |
LCD Displayer | Display the present testing circuit loop and insulation resistance value |
Indicator | Power indication, testing indication, RS485 communication |
Installation Mode | Guide rail installation or mounting screw installation |
Power Consumption | Standby 2W MAX 8W |
Dimension | 169mm×104mm×73mm |
Weight | Instrument weight: about 464g; total weight: about 0.6kg(include accessory) |
Working Temperature & Humidity | -20℃~60℃; below 80%RH |