http://oss.vluuke.com/upload/site/2025-02-08/80d25202502081309137942.png
VK8001 Dielectric Loss Power Factor Angle Tester
Hipots (High Voltage Testers)
Home > Products > Hipots (High Voltage Testers)
VK8001 Dielectric Loss Power Factor Angle Tester
  • VK8001 Dielectric Loss Power Factor Angle Tester
  • VK8001 Dielectric Loss Power Factor Angle Tester
  • VK8001 Dielectric Loss Power Factor Angle Tester
  • VK8001 Dielectric Loss Power Factor Angle Tester
  • VK8001 Dielectric Loss Power Factor Angle Tester
  • VK8001 Dielectric Loss Power Factor Angle Tester
  • VK8001 Dielectric Loss Power Factor Angle Tester
VK8001 Dielectric Loss Power Factor Angle Tester
VK8001 Dielectric Loss Power Factor Angle Tester
• 35-500kV CVT self-excitation test
• Reverse wiring high/low voltage shielding
• Automatic LCR parameter test
• Frequency conversion anti-interference technology
• Overcurrent safety protection
• Integrated HV power supply & standard capacitor
• Built-in wiring diagram prompt
$3550.00
  • Features
  • Specifications
  • Model
  • Accessories
  • Docs & Software

   Dielectric insulation test can effectively find out the deterioration of the insulation of electrical equipment, and the local defect, etc. It is widely used in the manufacture of electrical equipment, the installation of electrical equipment, the handover and the preventive test.

   The IT-DEL10 Dielectric Loss Power Factor Angle Tester employs frequency conversion power supply technology, utilizing microcontrollers and electronic components to achieve automatic frequency conversion, analog-to-digital conversion, and data processing. This results in strong interference resistance, rapid testing speed, high precision, and user-friendly operation.

    The frequency conversion power supply adopts a high-power switching power supply, output single frequency 50Hz/60Hz and double frequency 47.5Hz\52.5Hz, 45.0Hz\55.0Hz, 57.5Hz\62.5Hz, 55.0Hz\65.0Hz pure sine wave, automatic pressure, can provide up to 12kV voltage; automatic filtering of 50Hz interference, suitable for substations and other sites with high electromagnetic interference.


1

service condition

-15℃∽40

RH80%

2

anti-jamming principle

variable-frequency method

3

source

AC 220V±10%

generator with permit

4

high voltage output

0.5kV10kV

Every 0.1kV



 accuracy

2%



Maximum current

200mA



 capacity

2000VA

5

autogenerator

AC 0V50V/40A

Single frequency 50Hz, 60Hz adjustable  double frequency

45.0HZ/55.0HZ 47.5HZ/52.5HZ

55.0HZ/65.0HZ 57.5HZ/62.5HZ

6

resolution ratio

tgδ: 0.001%

Cx: 0.001pF

7

 accuracy

tgδ: ±(reading × 1.0% + 0.040%)



Cx: ± (reading *1.0%+1.00PF)

8

measuring range

tgδ

unrestricted



Cx

15pF Cx 300nF




10kV

Cx60  nF




 5kV

Cx150 nF




  1kV

Cx300 nF



CVT test

Cx300 nF

9

LCR measuring range

Inductance L> 20H (2kV)            

Resistor R> 10KΩ (2kV)


LCR certainty of measurement

1%

angular resolution

0.01

10

CVT gear ratio range

1010000

Phase test range

0359.999°


CVT gear ratio accuracy

1%

CVT ratio resolution

0.01

11

External dimensions (main unit) (mm)

40com*29cm*33cm


External dimensions (Attachment) (mm)

45cm*33cm*15cm

12

size of memory

200 groups support USB data storage

13

Weight (host)

25.62kg


Weight (Attachment Box)

5.66kg