http://oss.vluuke.com/upload/site/2025-02-08/80d25202502081309137942.png
ES7050 Power Distribution Line Fault Search Instrument
Earth Resistance Tester
Home > Products > Earth Resistance Tester
ES7050 Power Distribution Line Fault Search Instrument
  • ES7050 Power Distribution Line Fault Search Instrument
  • ES7050 Power Distribution Line Fault Search Instrument
  • ES7050 Power Distribution Line Fault Search Instrument
  • ES7050 Power Distribution Line Fault Search Instrument
  • ES7050 Power Distribution Line Fault Search Instrument
  • ES7050 Power Distribution Line Fault Search Instrument
ES7050 Power Distribution Line Fault Search Instrument
ES7050 Power Distribution Line Fault Search Instrument
★Output AC detection current :0-40±2mA
★Output AC detection voltage :0-3KV
★Output DC ground impedance current :0-36±2mA
★Output DC ground impedance voltage :0-2.7KV
★Detection line length:≤100km
$1715.00
  • Features
  • Specifications
  • Model
  • Accessories
  • Docs & Software
 Datum conditions 23℃±5℃
 Output AC detection current 0~40±2mA
 Output AC detection voltage 0~3kV
 Output DC grounding impedance current 0~36±2mA
 Output DC grounding impedance voltage 0~2.7kV
 Accuracy of grounding impedance current ±1.0mA
 Output accuracy of AC detection signal ±1.0mA
 output power Effective maximum output power 95W
 measuring range Grounding resistance ≤ 120k Ω
 Detect line length ≤100km
 Grounding impedance measurement 0~120 kΩ
 Measurement accuracy of grounding impedance Reading 5% ± 2k Ω
 Open circuit protection time of signal circuit ≤2S
 Protection time of signal output circuit integrity detection ≤2S
 Detection signal fluctuation alarm threshold±2mA
 Open circuit identification current threshold ≤2mA
 Low power alarm 24.5V
 Undervoltage power-off 23V
 No operation automatic power-off time 0.5~10Min
 display mode Dot matrix display, backlight function
 Rated operating voltage 25.9VDC
 Operating voltage range 23-29.4V
 Battery capacity 29.4V/9AH
 Power maintenance time Maximum power output>1.2 hours
 Operating ambient temperature 5℃~45℃
 Device size (mm) L465*W345*H185
 Unit weight Signal source 9.65Kg
 Detection method Clamp CT, integration mode
 transmission mode 433MHz wireless RF transmission, transmission distance is about 30m
 LCD size 62mm × 44mm
 Unit size 100mm long × 35mm thick × Height 204mm
 Jaw size Ф 50mm
 measuring range 0.1mA~1200A(50Hz)
 sampling frequency 0.1 mA~200 mA(22Hz)
 resolving power 2 times/second
 Test accuracy 0.1mA
 data storage ± 2% ± 5dgt (23 ℃± 5 ℃, below 80% RH)
 Line voltage 200 groups, "MEM" symbol indicates in the storage process, and "FULL" symbol flashes indicating that the storage is full
 Data retention Line electrification shall not exceed 35kV (operation with insulating rod)
 Data query In the detection mode, press the HOLD key to keep the data, the "HOLD" symbol is displayed, and then press the HOLD key to cancel
 the keeping
 Overrange overflow display MR symbol indicates that the stored data can be read up and down
 No signal indication OL A symbol display
 Automatic shutdown The "NO SIGNAL ----" symbol will be displayed dynamically when the recorder does not receive the transmission signal
 Power Supply If not detected, the device will shut down automati cally after about 15 minutes
 Battery voltage DC6V 4 No. 7 alkaline batteries, wireless reception:   5 No. 1.5V5 alkaline batteries
 Working environment temperature and  humidity

 Total weight of clamp meter and hand recorder is

 2.5Kg (including insulating rod and battery)

 Temperature and humidity of storage e nvironment -10℃~40℃; Less than 80% Rh
 Interference -10℃~60℃; Less than 70% Rh
 Insulating rod size Not interfered by 433MHz co frequency signal
 Insulation strength Telescopic link 0.9m/joint (4 joints)
 Structure AC 40kV/rms (between insulating rod and tong core)

 Drip proof type II