  • VKHVS-II Circuit Breaker Tester
  • VKHVS-II Circuit Breaker Tester
  • VKHVS-II Circuit Breaker Tester
  • VKHVS-II Circuit Breaker Tester
  • VKHVS-II Circuit Breaker Tester
  • VKHVS-II Circuit Breaker Tester
  • VKHVS-II Circuit Breaker Tester
  • VKHVS-II Circuit Breaker Tester
  • VKHVS-II Circuit Breaker Tester
  • VKHVS-II Circuit Breaker Tester
VKHVS-II Circuit Breaker Tester
VKHVS-II Circuit Breaker Tester
★Velocity measurement range: 0.1mm sensor 0.01~20.00m/s,345°angle sensor 1 cycle/ 0.01°
★Current resistance range: the maximum current 20 A, resolution: 0.01 A, 1000 Ω resistance, resolution: 0.01 Ω.
★External trigger voltage: AC/DC10-300V, current ≤120A
$1050.00
  • Features
  • Specifications
  • Model
  • Accessories
  • Docs & Software

With the development of society, the electricity security is required to be more by people, HVCB burdens the dual-control and protection in electric system, whose performance relates to the operation of electric system . mechanic parameter is one of indispensable parameter in analyzing the performance of breaker. The comprehensive characteristic tester of high-voltage switch , namely, the mechanic characteristic tester, is according to the latest version of < high-voltage AC circuit breaker> GB1984-2003 as design model, referring to the third part of PRC’s power industry standards <Genera technical specifications for high voltage test equipment>, and designing based on DL/T846.3-2004, which inspect various grades of voltages in high-voltage circuit breaker’s mechanic dynamic characteristic parameters about oil lack, oil excess, vacuum and sulfur hexafluoride, to provide convenience to many kinds of breakers.


1. Time measurement:

12 natural switching (closing) time

The opening (closing) phase is not at the same time

The difference between different periods of switching (closing)

Closing (opening) Bouncing time (number of bounces)

Internal trigger test range: 1ms ~ 10000ms, resolution: 0.01ms,

External trigger test range: 1ms ~ 10000ms,

Resolution within 999ms: 0.01ms,1000-9999ms: 0.1ms, and over 10000ms: 1ms.

Accuracy within 200ms: 0.05%± 0.1ms

2. velocity measurement : instant separating (instant closing) velocity

Appointed time slot( stroke segment or angle segment) average

velocity

3. velocity measurement range: 0.1mm sensor 0.01~20.00m/s,

                          345°angle sensor 1 cycle/ 0.01°

4. Travel measurement: Travel of moving contact (travel)

Contact stroke (open distance)

Over travel

Overshoot or rebound stroke

5. Measuring range: linear sensor: 50mm, measuring range: 0-50mm, resolution :0.1mm.

Optional 100-1000mm linear sensor of any length.

Encoder: 345° Rotate sensor, measurement

range: 0-1000mm, resolution :0.1о.

6. Current resistance range: the maximum current 20 A, resolution: 0.01 A, 1000 Ω resistance, resolution: 0.01 Ω.

7. Instrument power supply: AC 220V ± 10%; 50 hz plus or minus 10%

8. Dc power output: continuously adjustable DC20 ~ 270V, DC220V≤20A (short time), Power: 4400W.

9. External trigger voltage: AC/DC10-300V, current ≤120A

10. disconnecting switch measurement range

(1) Voltage output: DC20~270V(adjustable)

(2) Current output time: 0.01~10 s (settable)

(3) Fracture signal maximum acquisition time: 10s

(4) Measurable fracture closing, separation time, three-phase a synchronism , bounce time and frequency .

11. mainframe volume : 360×260×170mm

12. operating environment: -20℃~+50℃

13. relative humidity: ≤90%