http://oss.vluuke.com/upload/site/2025-02-08/80d25202502081309137942.png
LNJBC-II Single Phase Relay Protection Tester
Secondary Injection Relay Test Set
Home > Products > Secondary Injection Relay Test Set
LNJBC-II Single Phase Relay Protection Tester
  • LNJBC-II Single Phase Relay Protection Tester
  • LNJBC-II Single Phase Relay Protection Tester
  • LNJBC-II Single Phase Relay Protection Tester
  • LNJBC-II Single Phase Relay Protection Tester
  • LNJBC-II Single Phase Relay Protection Tester
  • LNJBC-II Single Phase Relay Protection Tester
  • LNJBC-II Single Phase Relay Protection Tester
LNJBC-II Single Phase Relay Protection Tester
LNJBC-II Single Phase Relay Protection Tester
★AC voltage:0~250V (adjustable)
★DC current:0~20A (adjustable)
★DC voltage:0~250V (adjustable)
★Fixed output DC voltage 24V 48V 110V 220V
★Time setting:0-9999.999s
★Resolution:0.1ms
$570.00
  • Features
  • Specifications
  • Model
  • Accessories
  • Docs & Software

The LNJBC-II Relay Protection Tester is a new generation of verification device developed based on the original JBC. The instrument's internal AC/DC voltage and current sources adopt the latest power technology, providing convenience for field personnel to apply the power instrument technology to other tests. While simplifying operation, this instrument also enhances functionality, allowing for the verification of various common relays. Its panel layout is compact and user-friendly, making it easy to operate and understand, thus earning widespread praise from users.


1.Output characteristic 

AC current: 

0~100A adjustable(200A customized) 

0~20A Adjustable 

0~5A Adjustable 

AC voltage:0~250V (adjustable) 

DC current:0~20A (adjustable) 

DC voltage:0~250V (adjustable) 

Fixed output DC voltage 24V 48V 110V 220V 

Time setting:0-9999.999s 

Resolution:0.1ms 


2.Power supply AC220V ± 5%, 50Hz ± 5%


3.Function

This instrument can calibrate the following types of relays or group protections: 

(1)Measuring relays: including current and voltage type relays, which can measure their starting value, return value, and coefficient.

(2) Time relay: It can measure its starting value, return value, and action time, with a time measurement error of no more than 0.2ms.

(3) Intermediate relay: Calibration of various intermediate relays with starting and holding coils, capable of measuring starting value, return value, holding value, and action time.

(4) Recloser relay: capable of conducting capacitor charging tests, charging time, reclosing time, and testing of intermediate components.

(5) Differential relay: capable of conducting DC excitation test, braking characteristic test, and volt ampere characteristic test.

(6) Various other uncommon relays.


Host

1 SET

Charger

1 PCS

Test Line

1 SET

Fuse

1 PCS

User Manual

1 PCS

Certificate

1 PCS


  • LNJBC-ll Single Phase Relay Protection Tester
©2024 Wuhan Lvnengde Precision Testing Technology Co., Ltd.Disclaimer: Part of the information on this site comes from the Internet, if there is any infringement, please contact customer service in time, we will deal with it as soon as possible